OPERATION
Water
Water enters the machine through the 3/8" male
flare at the rear of the cabinet, goes to the water
reservoir which it enters through the float valve.
The water then goes out the bottom of the
reservoir tank to the bottom of the evaporator.
Reservoir overflow or evaporator condensation is
routed to the drain.
WATER
INLET
RESERVOIR
ICE CHUTE
WATER LEVEL
EVAPORATOR
WATER INLET
DRIP PAN DRAIN
WATER SCHEMATIC
FME2400RH