Specifications
This ice machines is designed to be installed
indoors, in a controlled environment. It can operate
satisfactorily under a wide variety of conditions.
However, Do NOT operate the machine in
temperatures it has not been designed for. Do
NOT operate the machine above or below the
voltage limits for the particular model. Do NOT
operate the machine with too little or too much
water pressure.
Ice Machine Operational Limits
Minimum Maximum
Air Temperature 50
o
F. 100
o
F.
Water Temperature 40
o
F. 100
o
F.
Water Pressure 20 psi 80 psi
Voltage (60 Hz) 104 126
Remote Condenser Operational Limits
Minimum Maximum
Air Temperature -20
o
F. 120
o
F.
Voltage (60 Hz) 104 126
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
Bins:
Designed to fit a standard, 22" wide or wider open
top Scotsman Ice Storage Bin. Some examples
are:
BH360: Direct Fit
HTB555 - use KBT27
Bins with short or no baffles require the
addition of thermostat kit KSTAT-22 to lower
the ice level
Dispensers
ID150: Add adapter kit KBT42
HD22: Direct fit
Condensers
Single Circuit, 60 Hz: ERC111-1
Dual Circuit, 60 Hz: ERC211-1
Also, a Fan Relay Kit is needed when connecting
two ice machines to one condenser:
KCMR120 relay kit used with 115 volt 60 Hz
units
In addition, there may be other bins and
dispensers that can be used, check Scotsman’s
sales literature for application information.
Precharged Tubing:
25’ RTE25
40’ RTE40
75’ RTE75
CME456R
June 2004
Page 2
Model Number
Dimensions
WxDxH
(w/o bin)
Basic Electrical
(volts/Hz/phase)
Use Condenser
Refrigerant
Charge
R-404A
Minimum
Circuit
Ampacity
Maximum
Fuse Size
CME456RS-1C 22“ x 24" x 28" 115/60/1
ERC111-1A (1 ice
machine) or
ERC211-1A (2 ice
machines)
192 oz 20 20
Use precharged tubing kits, RTE25 (25’) or RTE40 (40’) or RTE75 (75’). Select the length closest to
the needs of the particular installation.