Water System
Batch type. Insulated water reservoir contains full water charge for each ice making cycle.
Water valve: Solenoid type. Opens to fill reservoir when mid sensor probe no longer makes a
circuit to the bottom probe. Closes when reservoir is full and top probe makes circuit to mid
probe.
Pump: Unsealed pedestal type, twist-release mounting
Water purge valve: Solenoid type. Opens to purge water during harvest cycle.
Water Level Sensor: Three probe conductivity.
Distributor: ABS plastic. Evenly distributes water over the evaporator surface. Slides off the
evaporator top. Removable cover for ease of cleaning.